Features

Trilogy100 Trilogy200
Trilogy100 and Trilogy200, unique features for unique patients

Versatility
Adapting to both patient and clinician environments, the Trilogy series fits with a circuit with a leak (‘Passive Circuit’) or a circuit with a Valve (‘Active circuit with PAP’ and ‘Active circuit with Flow’*) delivering for all configurations volume control or pressure control ventilations, through either non-invasive or invasive interfaces to meet the needs of adult and paediatric patients (> 5 kg) alike.
This built-in flexibility means the Trilogy Series can treat a wide range of respiratory conditions, including those that require frequent changes to the patient’s prescription.
*‘Active with Flow’ circuit type is available in the Trilogy200 only.

Performance
When configured with the passive circuit, the Trilogy Series provides the following Philips Respironics well known technologies:
• Advanced leak compensation in invasive and non-invasive ventilation for pressure modes, as well as – for the first time ever – volume modes.
Auto-TRAK algorithm providing automatic trigger and cycle thresholds to maintain optimum sensitivity eliminating the need for adjustments.
AVAPS (Average Volume Assured Pressure Support) hybrid ventilation in pressure modes for invasive and non-invasive modalities.
The Trilogy200 fits with a circuit type ‘Active With Flow’ using a single limb circuit with an active exhalation valve and a proximal flow sensor. This proximal flow sensor allows accurate exhaled gas measurement as well as advanced flow triggering sensitivity and leak compensation for the most difficult patients.

Simplicity
Whether it’s being used for hospital titration or in the home, the Trilogy Series have an intuitive interface that combines ease of use with access to high levels of versatility and performance.
The Trilogy Series portable ventilators offer up to 6 to 8 hours battery capacity for continuous autonomy, giving patients the freedom they deserve.

Close patient follow-up for long-term efficacy

Trilogy100 is fitted with a SD card that stores all necessary ventilation data. This data is displayed by Directview software, which manages patient ventilation therapy and identifies when any adjustments are necessary to maintain an effective treatment. DirectView also offers a complete set of ventilation reports that are fully customizable depending on the practice and/or patient’s disease. Furthermore, ventilation data can be exported for supplementary analysis in a number of statistical applications.
DirectView provides a complete view into respiratory therapy for improved patient care:

  • 72 hours of raw data to monitor a patient’s breath-by-breath waveform
  • Daily details, displaying the patient’s therapy for the past 30 days
  • Trend overviews of the past 12 months displaying pressure, breath rate, percentage of triggered breaths, peak inspiratory patient flow, estimated exhaled tidal volume, leak, Ti/Ttot and minute ventilation

Trilogy Series

 

Circuit type
Passive Active with PAP Active with Flow
Ventilation type Volume and pressure modes for non-invasive and invasive modalities
Minimum PEP of 4 required Allows 0 PEP Allows 0 PEP
Leak
compensation
performance
+++ +
(minimum bias flow of 10LPM)
++
(minimum bias flow of 10LPM)
Triggering Auto-TRAK & flow Flow Advanced flow triggering
Exhaled gas
monitoring
Estimation no Measurement
Trilogy100 YES YES --
Trilogy200 YES YES YES